Toshiba heat pump repairs in East Auckland
Toshiba gone dead, or showing a code beside a little spanner on the remote? We fix Toshiba heat pumps across East Auckland, from the outdoor unit in.
- Repairs first
- Fault-finding and repairs, then servicing
- Electrician by trade
- Faults on the power side are his trade
- Since 2012
- Fixing heat pumps for 13 years and more
- All the main brands
- Mitsubishi, Fujitsu, Daikin and more
- Brand
- Toshiba
- Part
- Wiring between the units
- Code
- E04
- Look at
- Cable, indoor and outdoor boards
When the two units stop talking, nothing runs.
Send us your Toshiba faultWhen the units stop talking
The indoor and outdoor units talk over the wiring that runs between them. When that link drops, nothing runs. The cause is the wiring itself or the board at either end, and that’s electrical work.
That’s electrical work, and Phil’s an electrician by trade.
Fan, sensors and the outdoor board
A Toshiba has a fault of its own for the outdoor fan drive, the outdoor coil and air sensors, the discharge sensor and the outdoor board. On the wired remote of the larger high-wall units, the code shows beside a blinking spanner.
Hold set and test together for four seconds and it shows the last four codes. Leave the CL button alone, because it wipes the history we’d want to see.
Preheat and defrost
In heating, a Toshiba warms up for about five minutes before it blows warm air, and the fans stop while it defrosts. On units with a preheat/defrost light, that light being on is normal.
It also won’t start for three minutes after a sudden restart.
After a power cut
Newer Toshiba wall units, the Shorai Edge, Shorai and Seiya, come back on by themselves after a power cut. Some older models and the floor console stay off until you restart them.
Out by the bays
A Toshiba outdoor unit facing the water at Bucklands Beach or Half Moon Bay gets the salt on its fins, casing and fixings like any other. We look those over whenever we’re out.
Toshiba heat pumps come through AHI Carrier in New Zealand, so older units may be badged Toshiba Carrier. Same unit, and we fix both.
Before you pick up the phone
- Lights dark but it’s running? The brightness may be turned down. Hold the fan button for three seconds.
- Timer light on after you switch off? On some models that’s a drying run, not a fault.
- Wired remote showing a code? Note it, and leave the CL button alone.
The other brands we see most
- Mitsubishi ElectricMUZ outdoor units, the blink count and defrost
- FujitsuThe label on the outdoor unit, and the fan fault
- PanasonicTimer light faults and the outdoor coil sensors
- DaikinDefrost noises and an outdoor board running hot
- HitachiDefrost, steam and the orange timer light
We also work on LG, Samsung, Haier, Gree, Carrier and Temperzone.
Toshiba questions
Still wondering? Ring 0800 211 406 or ask in the form.
Do you repair Toshiba heat pumps in East Auckland?
Yes, Toshiba and Toshiba Carrier, from Pakuranga and Botany out to Howick and Bucklands Beach.
My Toshiba won’t do anything. Where do I start?
Check the breaker, then send us any code on the remote. A broken link between the two units stops everything, and that’s one we find.
Why didn’t my Toshiba come back on after a power cut?
Some older models and the floor console stay off after a cut. Newer wall units restart by themselves.
Send us your Toshiba fault
The brand’s already picked. Add what the unit’s doing, any code and a photo of the label, and we’ll call you back.
Thanks, that’s come through.
We’ll call you back to find a time that suits.
Handy to send
- A photo of the label on the outdoor unit
- What you can see or hear, and when it started
- How close you are to the water
- Any code on the remote or the indoor unit’s lights
- Send it, or ring us.
- We call you back to find a time that suits you.
- We find what’s failed and explain the fix before we start on it.
We’re open weekdays from 9 till 5, and Saturdays 9 till 4.