Daikin heat pump repairs in East Auckland
Daikin whistling on a cold morning, or stopping on the hottest afternoon of the year? We fix Daikin heat pumps across East Auckland, outdoor unit first.
- Repairs first
- Fault-finding and repairs, then servicing
- Electrician by trade
- Faults on the power side are his trade
- Since 2012
- Fixing heat pumps for 13 years and more
- All the main brands
- Mitsubishi, Fujitsu, Daikin and more
- Brand
- Daikin
- Part
- Outdoor board running hot
- Code
- L4
- Look at
- Fan, coil, airflow
A clogged coil or a slow fan stops the outdoor board cooling itself.
Send us your Daikin faultStopping on the hottest days
A Daikin’s outdoor unit has an inverter board that has to shed its own heat. When it runs too hot, the unit stops, and the causes Daikin lists start with the outdoor fan and a dirty outdoor coil.
High pressure in cooling has the same sort of list: a blocked coil, poor airflow round the unit, or the fan.
The outdoor fan
If the outdoor fan motor fails, or something jams it, the operation light blinks and the unit stops. Debris in the fan is on Daikin’s own list of causes, beside the motor and the outdoor board.
It’s normal for the outdoor fan to run on for about a minute after you switch off, and to start by itself on a very hot day.
Whistling in winter
In heating, a Daikin stops now and then for 4 to 12 minutes to defrost. You might hear a whistle or a sound like running water, and see steam coming off the outdoor unit. That’s normal.
If it stops with the operation light steady rather than blinking, that’s protection after a swing in the power supply, and it comes back on in about three minutes.
Getting the code
A blinking operation light means a fault. Hold the cancel button on the remote for about five seconds, then keep pressing it until you hear a long beep. The code showing then is the one to send us.
Near the water
At Bucklands Beach or Eastern Beach, salt air sits on a Daikin’s fins and casing like any outdoor unit’s. On a coastal unit, we look closely at the fins and the casing.
On many Daikin outdoor units the model plate is on the right-hand side panel, by the pipe and wiring cover. On the indoor unit the model label is on the lower right of the front edge.
Before you call
- Turn the breaker off, then check nothing is blocking the outdoor unit’s air in or out.
- Stopped with the operation light steady? Wait three minutes. It restarts itself.
- Light still blinking after a restart? Read the code and send it to us.
The other brands we see most
- Mitsubishi ElectricMUZ outdoor units, the blink count and defrost
- FujitsuThe label on the outdoor unit, and the fan fault
- PanasonicTimer light faults and the outdoor coil sensors
- HitachiDefrost, steam and the orange timer light
- ToshibaWiring between the units, preheat and defrost
We also work on LG, Samsung, Haier, Gree, Carrier and Temperzone.
Daikin questions
Still wondering? Ring 0800 211 406 or ask in the form.
Do you repair Daikin heat pumps in East Auckland?
Yes, from Pakuranga and Botany to Flat Bush, Howick and the bays.
Why does my Daikin whistle and steam in winter?
That’s defrost. The outdoor unit melts the frost off its coil for a few minutes, then carries on heating.
Why does the outdoor fan keep going after I turn my Daikin off?
It runs on for about a minute after the unit stops. On a very hot day it can start by itself, too.
Send us your Daikin fault
The brand’s already picked. Add what the unit’s doing, any code and a photo of the label, and we’ll call you back.
Thanks, that’s come through.
We’ll call you back to find a time that suits.
Handy to send
- A photo of the label on the outdoor unit
- What you can see or hear, and when it started
- How close you are to the water
- Any code on the remote or the indoor unit’s lights
- Send it, or ring us.
- We call you back to find a time that suits you.
- We find what’s failed and explain the fix before we start on it.
We’re open weekdays from 9 till 5, and Saturdays 9 till 4.