Mitsubishi Electric heat pump repairs in East Auckland
Mitsubishi Electric outdoor unit stopped, a lamp blinking at you from the lounge, or a casing crusted with salt off the bay? We fix them across East Auckland, from the outdoor unit to the wiring between the two.
- Repairs first
- Fault-finding and repairs, then servicing
- Electrician by trade
- Faults on the power side are his trade
- Since 2012
- Fixing heat pumps for 13 years and more
- All the main brands
- Mitsubishi, Fujitsu, Daikin and more
- Brand
- Mitsubishi Electric
- Part
- Outdoor power fault
- Lamp
- 5 blinks, then a pause
- Outdoor unit
- MUZ on the label
Both units stop. Count the blinks and put the number in the code box.
Send us your Mitsubishi faultMost of its faults point outside
Most of the faults a Mitsubishi Electric wall unit can blink out point to the outdoor unit or the wiring out to it, and most of those are electrical.
The outdoor unit is where the inverter board, the sensors and the fan motor live, and Phil’s an electrician by trade.
When the outdoor unit keeps giving up
If the outdoor fan stops three times in a row soon after starting, the outdoor board logs a fan fault and retries every three minutes, so your heat comes and goes. The fan motor or the inverter board is behind it.
A failed outdoor temperature sensor, such as the defrost or coil sensor, stops the indoor fan and sets the lamp blinking in a count. Put the count in the form, and we know which part of the outdoor unit to look at first.
Steam and a pause on cold mornings
In heating, a Mitsubishi Electric stops to defrost for anything up to about ten minutes. The indoor fan slows or stops, the vane goes flat, and the outdoor unit drips and gives off what looks like smoke. It’s steam, and the heat comes back by itself.
Switch it off and straight back on, and it waits about three minutes before it starts. That protects the compressor.
Reading the label
The model and serial number are on the label on the indoor unit. Wall units start MSZ, and the outdoor unit that goes with them starts MUZ (MXZ when it runs more than one room). New Zealand models end in a D.
A photo of that label is all we need to know exactly what you’ve got.
A Mitsubishi outdoor unit by the water
Out at Bucklands Beach or Cockle Bay, the outdoor unit takes the salt. It settles on the coil fins and the casing, and you see it on the screws and the bracket bolts.
Inside that casing, the outdoor board has a fault lamp of its own that only shows with the covers off. Reading it is part of how we pin down an outdoor fault.
Mitsubishi Heavy Industries is a different maker
If your indoor label starts SRK, you’ve got a Mitsubishi Heavy Industries unit, not a Mitsubishi Electric. Different maker, different manuals and different fault lights.
We fix those too. Say it’s an SRK in the form, and add a photo of the label.
Before you ring
- Steam and dripping water at the outdoor unit, and no heat for a bit? Give it ten minutes. That’s defrost.
- Just switched it off and on? Wait three minutes before deciding it’s dead.
- Remote doing nothing? Fresh batteries, then press RESET on the remote.
- Breaker tripping, or the lamp blinking? Switch it off and send us the count.
The other brands we see most
- FujitsuThe label on the outdoor unit, and the fan fault
- PanasonicTimer light faults and the outdoor coil sensors
- DaikinDefrost noises and an outdoor board running hot
- HitachiDefrost, steam and the orange timer light
- ToshibaWiring between the units, preheat and defrost
We also work on LG, Samsung, Haier, Gree, Carrier and Temperzone.
Mitsubishi questions
Still wondering? Ring 0800 211 406 or ask in the form.
Do you fix Mitsubishi Electric heat pumps near the sea?
Yes, from Half Moon Bay and Bucklands Beach to Howick and Pakuranga. We look at the outdoor unit, its fan and board, and what the salt has done to the casing and fixings.
My Mitsubishi keeps stopping and starting. What’s wrong?
It can be the outdoor fan stopping and the unit retrying, or the outdoor board protecting itself because the unit can’t breathe. Clear anything piled against the outdoor unit and tell us what the lamp is doing.
Is mine a Mitsubishi Electric or a Mitsubishi Heavy Industries?
Check the indoor label. A model starting MSZ is Mitsubishi Electric; SRK is Mitsubishi Heavy Industries.
Send us your Mitsubishi fault
The brand’s already picked. Add what the unit’s doing, any code and a photo of the label, and we’ll call you back.
Thanks, that’s come through.
We’ll call you back to find a time that suits.
Handy to send
- A photo of the label on the outdoor unit
- What you can see or hear, and when it started
- How close you are to the water
- Any code on the remote or the indoor unit’s lights
- Send it, or ring us.
- We call you back to find a time that suits you.
- We find what’s failed and explain the fix before we start on it.
We’re open weekdays from 9 till 5, and Saturdays 9 till 4.